 Description
|
This capacitive filling level
sensor determines the filling level of reservoirs
up to a height of 300 mm. The sensor is mounted on
the side of the reservoir or can project directly
into the material.
|

|
|

|
The analog output signal is
created from the sum of the 10 sensor segments
which are arranged in series and covered with the
filling material. Additionally, 10 LEDs, arranged
at the back of the unit, show the filling level.
The advantage of this system of measuring is that
mistakes due to contamination on the surface of the
reservoir or sensor is avoided.
The capacitive sensor sees the
filling material through walls of plastic or glass.
Depending on the material, the thickness of the
plastic or glass can be up to 20 mm.
|
|
 Application
|
In grinding mills, the output of
conveyor belts depends on an optimum supply of the
material to be milled. During this process, a large
volume of material has to pass through a small
storage reservoir. This requires precise
measurement of the level in a glass or plastic
reservoir.
|
|
|
|
This bar shaped capacitive
sensor monitors the level of the material through
the reservoir wall and gives an analog output
signal which controls the flow from the conveyor
belt.
|
|
 Assembly
|
The sensor is mounted by means
of two screws at the foot of the reservoir so that
the active surface is against the reservoir
wall.
|

|
|
|
|
|
|
 Adjustment
|
After the supply voltage is
connected, the adjustment made at the factory can
be checked by filling and emptying the
reservoir.
|

|
|
|
|
|
|
 Mounting
Considerations
|
Everything in the area of the
active surface of the sensor changes the
capacitance seen by the oscillator and thus alters
the switching distance of the sensor. The extent of
the change depends on the kind (conductivity,
dielectric, ground), size and distance of the
medium. Thus, humidity, dust, ambient temperature
and coverage of the sensor can change the way it
operates.
|
|
|
|
|
|
 Technical
Data
|
|
Type
|
KKU 002.19
|
|
Measuring height (filling
range)
|
300 mm
|
|
Measuring distance
|
0-20 mm
|
|
Output (load > 10 kOhm)
|
0-10 V
|
|
Resolution
|
10%
|
|
Measuring distance
(adjustable)
|
yes
|
|
Supply voltage
|
24 VDC +10/-15%
|
|
Ripple voltage
|
max. 15%
|
|
No-load current
|
max. 60 mA
|
|
Response time
|
0.5 s.
|
|
Readiness delay
|
1 s.
|
|
Ambient temperature
|
-10 to +70°C
|
|
Protection class
|
IP 67
|
|
Connection
|
3 m cable
|
|
Function display
|
LED
|
|
Housing material
|
Plastic
|
|
Weight
|
1.2 kg
|
|
|